Change from Celsius to Fahrenheit

I have a 2005 Sundance Cayman 780 series. Just replaced the Circuit board. Everything working great now but the temperature is displaying in Celsius. Can it be changed to Fahrenheit?

Replies

  1. Nigel

    Reply

    Paul remove logic jumper pin 7-8 to toggle back to degrees F.

  2. BRIAN

    Reply

    I just changed my board which was a 6600-268 to the new replacment 6600-724. The old board had the 7-8 pins, new one i dont see it. Any help??

    • Nigel

      Reply

      Brian if it is a Genuine Sundance Spas PWA it will have a set of jumper pins just to the left of where you plug in the topside control.
      Jumper 1-2 on enables 15 amp logic, Jumper 1-2 on enables 30 amp logic, Jumper 1-2 off enables 40 amp logic
      Jumper 3-4 on not used, Jumper 3-4 off enables 1 pump operation
      Jumper 7-8 on enables Celsius temperature display
      Jumper 7-8 off enables Fahrenheit display
      This genuine board also has surface mount terminals for the heater where you old PWA likely did not.

  3. Nile

    Reply

    changing pool celsius to fahrenheit.

    • Nigel

      Reply

      Hi Nile. Which model/make of controller are you trying to switch from Celsius to Fahrenheit?

  4. Vicky Thibodeau

    Reply

    We replaced our mother board and now the hot tub is reading is Celsius. We have a Masterspa Downeaster. Any ideas how to switch back to Fahrenheit?

    • Nigel

      Reply

      Hi Vicky. The temperature toggle is typically controlled by one of the dip switches in the bank set of switches on a Balboa board in a Downeast spa. If the new board you put in is a direct match for the old one you should be able to follow the schematic on the back of your control box cover. It will indicate which switch toggles from farenheit to celsius. If you purchased an offshore board you may have to contact who you purchased it from if the bank of switches don’t match your old board. It’s recommended to reset persistent memory as well after changing a dip switch if it’s a genuine Balboa board.

  5. Jacob Morgan

    Reply

    I have the same problem with a 2009 hotsprings Prodigy. I replaced the old board with a new board I bought direct from hotsprings, but now the temp. Is in celcius and theres no way to change it back to Fahrenheit from the topside control. Any ideas? Thanks for the help

    • Nigel

      Reply

      Hi Jacob. If your Prodigy has the proprietary Watkins controller you should be able to adjust one of the board jumpers to toggle between Celsius and Fahrenheit. Typically the schematic on the back of the controller cover will tell you which jumper. If they switch to a Balboa system already on yours you will be able to toggle one of the dip switches in the dip switch bank. The back of the controller cover will also tell you which dip switch to move.

  6. Steven Thompson

    Reply

    I have an Apollo Spas Cascade model from around 2013 or 2014. We lost power and the display changed from °F to °C. I don’t do the math so good any more so converting on the fly suuuuux. How do I Americanize it again? It has happened before and I forgot the button sequence to push.

    • Nigel

      Reply

      Hi Steven. Is it a Gecko controller or a Balboa controller on that Arctic spa?

  7. Dave Comeau

    Reply

    How can I change my Beachcomber 590 from Fahrenheit to Celsius???

    • Nigel

      Reply

      Hi Dave. Does your Beachcomber have a Balboa controller box?

  8. Dave Comeau

    Reply

    Hi Nigel, it is a Balboa. Sorry, it isn’t allowing me to reply so I have to this way.

    • Nigel

      Reply

      Dave, on the back of your control box cover there is a schematic. It shows where all your dip switch setting are and the function they perform. There is dip switch for Fahrenheit/Celsius there.

  9. Matt

    Reply

    Changed our mother board on a Sundance and now it is reading Celsius? We need Fahrenheit

    • Nigel

      Reply

      Hi Matt. What is the part number of the board you purchased?

  10. Nathaniel

    Reply

    I have a J345 Jacuzzi brand manufactured in 2004. Changed circuit board, now in celcius. My control panel on top only has 5 buttons ( 1- +, 2 –, 3- light, 4- 1st pump, 5- 2nd pump). The J300 series manual doesn’t cover changing to Fahrenheit.

    • Nigel

      Reply

      Hi Nathaniel. The temperature conversion setting is done through the PWA jumpers. If you give me the part number of your PWA I may be able to help. Alternatively the person who replaced your PWA should be able to set the jumper for you.

  11. Jackie

    Reply

    How to change a circuit board from Celsius to Fahrenheit mines is a jacuzzi 2008

    • Nigel

      Reply

      What’s the part number on your circuit board Jackie?

  12. Fred harwood

    Reply

    Hello I have the same tho g going on as Nathaniel in the comments above with my J 345 jacuzzi, the circuit board I just replaced is a 6600-726.
    Thanks.

    “I have a J345 Jacuzzi brand manufactured in 2004. Changed circuit board, now in celcius. My control panel on top only has 5 buttons ( 1- +, 2 –, 3- light, 4- 1st pump, 5- 2nd pump). The J300 series manual doesn’t cover changing to Fahrenheit”

    • Nigel

      Reply

      Jumper 7-8 on will give you celsius reading. Jumper off will give you Fahrenheit.

  13. Mike Swinehart

    Reply

    I have board #6600-726 on a Sweetwater Bahia Spa. How do I switch to Farenheit?

    • Nigel

      Reply

      Removing the jumper pin on pins 7-8 should get you Fahrenheit readout Mike.

  14. Melissa

    Reply

    Just changed my circuit board onj310 jacuzzi what is jumper 5-6 for and does 3-4 stay on

    • Nigel

      Reply

      What’s the part number of the circuit board you just installed?

  15. Scott Menard

    Reply

    I have a leisure bay G2 spa. Temp is reading celcius. How can I change it to Fahrenheit?

    • Nigel

      Reply

      Is it a Balboa model spa pak controller that you have?

      • Nigel

        Reply

        If you take off the front cover of your controller there should be a schematic on the back of the cover. It should show a set of 10 dip switches that correlate to your circuit board. One of the dip switches is a toggle between Celsius and Fahrenheit.

  16. Manon

    Reply

    Bonjour , on viens de changer la carte imprimer de notre spa sundance certa 780 2007,

    Et notre chute ne fonctionne plus en continue comme avant?! Mais juste quand l’eau chauffe, est-ce possible de la remettre en continue ?

    Merci à l’avance de votre réponse

    • Nigel

      Reply

      Where did you buy the circuit board from Manon?

Ask a Question or Comment