How to reset code 616

Changed clear ray bulb

13 thoughts on “How to reset code 616”

  1. Rick what your are seeing is the blb or (bulb) message. This is an indication that your ClearRay bulb needs to be replaced and your quartz tube cleaned. I would recommend you do this before resetting your countdown timer.

    To reset your countdown timer hold the Jet 1 and cooler buttons for 3 seconds, you will see your filter cycle indicator come up. At this point press the warmer button until you see 0.

    Once you see 0 press the Jet 1 button and your ClearRay countdown timer should reset. If the countdown timer was at 0 the Jet 1 button will reset it. If the countdown timer was not at 0 the Jet 1 button will not reset it. All of this info is also on page 32 of your owners manual. If all else fails contact our Service Support Desk to book service of your ClearRay system.

  2. I own a 2010 Jacuzzi J300 hot tub and this morning the 616 code flashed on my LED display. I am also 100% certain that I have the ozonator system instead of the UV bulb system. Using your instructions above, the 616 code cleared. My question is this,, does this mean my ozonator has craped out and needs replacing.

    1. Mike usually the ClearRay bulb countdown timer is set for 365 days. Depending on the type of ozone unit you have installed ie Uv or Corona discharge they start having diminished impact after 1-3 years. If you require a new ozone unit visit our online store at http://www.aqua-tech.ca. Click on Parts And Accessories and then click on the big yellow button Prices and Availability. You can attach a picture of your current ozone unit and plug here for id purposes.

  3. I have a Sundance spa and the display just started flashing the temperature and the b1b. What should I do

    Thanks Cindy

  4. How to change the time for hot tub to run automatically for one hour. It currently starts at 130 am and runs for an hour. Would like to change time to run to afternoon 130pm.

  5. Jackalyn Oldham

    I have an 880 series sundance hot tub spa…we just had the transformer replaced yesterday now today it is displaying blb. Is the bulb really out or is it something to do with the transformer? It is only 4-5 years old.jackwi

  6. I have a 2007 sundance optima spa 880 with the blb error. i tried to reset it as per some of the suggestions found here but no luck. is there a different way for this particular model?

    1. David these are the instructions: 12.8 Programming the CLEARRAY® (Ultraviolet) Water
      Purification System
      To access the programming options follow the step below.
      • Standard Mode – in this mode, press the (CYCLE) button three
      times;
      • Economy Mode – in this mode, press the (CYCLE) button
      seven times to enter the programming mode.
      The LCD screen will display “U.” At this time the system is ready to
      accept your changes.
      1. Press the (SELECT) button once. The current status of the
      CLEARRAY System appears on the LCD display, either “ON” or
      “OFF.”
      2. Press the (UP) or (DOWN) button to change the status
      of the CLEARRAY System from either “ON” to “OFF.”
      Note: If the “OFF” option is selected, then there is no need to continue
      with the steps below. Selecting “OFF” disables the duration countdown
      timer. Press the (DISPLAY) button to return to the water temperature display.
      3. Press the (SELECT) button to access the duration countdown
      timer.
      4. Press the (UP) button to program the duration countdown
      timer to 365 days. If the timer is not at “0” pressing the “UP”
      button will not reset it.
      Note: You can only program the duration if the number of days is at “0”
      days or the LCD display is flashing “blb.” Pressing the (UP) button at any other reading will not change it