Hot tub breaker

Hello. I went to turn on Sundance hot tub and the breaker switches off within a couple seconds on the tub. What is most likely cause? Can I diagnose by opening panel?

Thanks.

3 thoughts on “Hot tub breaker”

  1. Hi Tony. If you have an ozone unit unplug it and see if your breaker holds with it unplugged. If you have no ozone try and disconnect your heater from the board and see if the breaker holds. If the breaker still trips with the ozone and heater disconnected try and disconnect the circ pump and see if the breaker holds. If the breaker holds with one of these appliances disconnected you could have a bad ozone, heater or circ pump.

Leave a Reply

Your email address will not be published. Required fields are marked *